iGeneTech Bioscience Co., Ltd.
EN

Library Preparation in 3 Steps: iGeneTech Automated Reagent Strip Ultra-Simplifies NGS Workflow

Table of Content [Hide]

    In modern genomics research, sequencing library preparation is a critical step that determines data quality and experimental efficiency.

    To address this, iGeneTech has launched premixed reagent (reagent strip) products. When paired with the IGT-AS12 Automated Workstation, these products feature simple operation and quick setup, enabling ready-to-load, ready-to-retrieve, and ready-to-use functionality. They help researchers rapidly and stably obtain high-quality libraries.

    Experimental Workflow of IGT-AS12 Automated Library Preparation Premixed Reagents (Reagent Strips)

    Deploy Consumables → Run Program → Library Quality Control

    自动化建库1.png 

    Product Introduction

    Automated Enzymatic Digestion Library Preparation Kit

    Name: IGT® Enzyme One-Strip

    IGT® Enzyme One-Strip is a universal enzymatic digestion DNA library preparation kit specifically developed for the IGT-AS12 Automated Workstation. It is compatible with the following sample types: gDNA, formalin-fixed paraffin-embedded (FFPE) gDNA, etc.

    自动化建库2.png 

    自动化建库3.png

    Automated Rapid Library Preparation Kit

    Name: IGT® Fast One-Strip

    IGT® Fast One-Strip is a universal double-stranded DNA (dsDNA) library preparation kit specifically developed for the IGT-AS12 Automated Workstation. It is compatible with sample types such as cell-free DNA (cfDNA), formalin-fixed paraffin-embedded (FFPE) gDNA, etc.

    自动化建库7.png 

    Product Features

    1. Zero Reagent Waste

    Each sample uses one library preparation reagent striptake exactly the number of strips needed for the number of samples, truly achieving zero waste!

    2. Time and Labor Saving

    The IGT-AS12 Automated Workstation comes with built-in automated workflows. After opening the workflow, image markers and text descriptions assist operators in quickly and accurately deploying the consumables, samples, and reagents required for the current automated process.Operators can start operating on the same day after training. Compared with manual operations, this solution saves researchers approximately 60 minutes of reagent preparation and aliquoting time.

    3. Ready-to-Use

    The IGT-AS12 Automated Workstation pre-installs standardized experimental workflows for iGeneTech kits. No reassembly is required after the equipment arrives at the laboratory; it can be put into use immediately after calibration.When paired with IGT-AS12 automated premixed reagents (reagent strips), it enables "ready-to-load, ready-to-retrieve, ready-to-use" functionality. This saves users approximately 2-4 weeks of time for automated workflow programming and experimental reagent validation, truly achieving "no waiting required."

    4. Flexible Throughput

    The automated experimental workflows provided by the premixed reagents (reagent strips) for the IGT-AS12 Automated Workstation offer flexible throughput, supporting 1-16 reactions per run (throughput can be doubled with multiple units working collaboratively). It is suitable for small and medium-sized NGS gene capture laboratories, such as third-party testing laboratories, hospital departments, public health and government agency laboratories, and research institutions.

    IGT® Enzyme One-Strip Data Performance

    01 Excellent Library Yield with Various Input Amounts

    IGT® Enzyme One-Strip is compatible with library preparation from samples of various input amounts. When amplified according to the recommended number of cycles, it delivers high-efficiency library yield.

    自动化建库4.png 

    Figure 1. Library Yield Performance of IGT® Enzyme One-Strip with Different Input AmountsThe sample used was gDNA (G3041, Promega), with input amounts of 50 ng and 200 ng for library preparation, respectively. The indexed primer kits employed were IGT® UDI Primer 1-96 (for Illumina) and IGT® UDI Primer 1-96 (for MGI). Enzymatic digestion was performed for 30 minutes, with 7 cycles and 5 cycles of amplification, respectively.

     

    02 Controllable Insert Size of Libraries

    By adjusting the enzymatic digestion time, the insert size of libraries can be flexibly controlled with stable library yield.

    自动化建库5.png 

    Figure 2. Library Preparation Performance of IGT® Enzyme One-Strip with Different Enzymatic Digestion TimesThe sample used was gDNA (G3041, Promega), with an input amount of 200 ng for library preparation. The enzymatic digestion times were 10 and 30 minutes, respectively, and the PCR cycles were set at 5.

    IGT® Fast One-Strip Data Performance

    自动化建库6.png 

    Figure 3. Library Yield Performance of IGT® Fast One-Strip with Different Input AmountsThe sample used was gDNA (G3041, Promega). The gDNA was sonicated to 150200 bp, with input amounts of 1 ng, 10 ng, and 100 ng for library preparation, respectively. The indexed primer kits employed were IGT® UDI Primer 1-96 (for Illumina) and IGT® UDI Primer 1-96 (for MGI), with 13, 10, and 6 cycles of amplification, respectively.

     

    Product Info

    Product Name

    Speci.

    Cat. No

    IGT-AS12 Automated Liquid Handling Workstation

    Configuration III

    Q91013

    IGT® Enzyme One-Strip (ILM-UDI)

    96 rxn

    C11692

    IGT® Enzyme One-Strip (MGI-UDI)

    96 rxn

    C11702

    IGT® Fast One-Strip (ILM-UMI)

    96 rxn

    C11752

    IGT® Fast One-Strip (MGI-UMI)

    96 rxn

    C11762

     

     

     

     


    References