AIExome® Human Exome Panel V5 is designed based on human reference genome GRCh38 and GRC. It covers about 34.69 Mb CDS region, and the probe coverage size is only 48.17 Mb, ensuring maximum coverage of the protein-coding region. AIExome® V5 has also been optimized for probe coverage of reference genome patches, high repeat regions and high GC content regions. AIExome® V5 series has 3 different versions and are open to semi-customization, where customers can add or enhance probes for regions of interests based on standard AIExome® V5.
Panel Number | T1248V1hg38 |
Technical Platform | TargetSeq® Hybridization Capture Sequencing |
Coverage Size | 34.69 Mb |
Reference Database | CDS (RefSeq & refGene)*, MANE, CCDS |
Reference Genome | GRCh38 (hg38) and GRC |
Coverage | NCBI RefSeq CDS +UCSC refGene CDS |
Storage | ≤-20℃ |
Recommend Sequencing Read Length | PE150 |
Recommend Sequencing Data Size and Depth | Illumina: 9 Gb/ 100X |
MGI: 7 Gb/ 100× |
Panel designed based on GRCh38 and GRC and recent patch sequences, covering over 100% of the CDS regions in major genetic databases.
High accuracy with optimized probe design for repeat regions and high GC content regions.
Rigorous quality control with high MAF internal reference QC SNPs.
Upgraded TargetSeq One® v3.0 kits and workflow for easier use and more reliable experiments.
Compatible with automated workflow to reduce manual operation and human errors.
Stable data reproducibility across different NGS platforms, with excellent data performance and outstanding cost-efficiency.
AIExome® V5 excellent probe design, combined with the TargetSeq One® v3.0 hybridization system, achieves higher capture efficiency and superior uniformity compared to competitors.
AIExome® V5 has achieved a breakthrough in the Fold 80 uniformity index, reaching 1.24. When combined with the latest 2-hour rapid hybridization capture protocol, Fold 80 remains stably controlled at 1.5-performance far exceeding that of market competitors. The data indicators are as follows:
AIExome® V5 demonstrates a flank reads capture rate of 91%, with 20%× coverage rate reaching 99% and 50%× coverage rate reaching 96%.
AIExome® V5 Core Edition demonstrates stable and excellent performance across different sequencers.
100× estimated data volume: Illumina platform: 9 Gb/sample & MGI: 7 Gb/sample
In the same batch test of 30 μL/15 μL hybridization systems, the 15 μL system shows higher uniformity, allowing customers to choose based on their needs.
Product Name | Set | Cat. No |
AIExome® Human Exome Panel V5 | 24 rxn | PH2006465 |
96 rxn | PH2006462 |